Filter
Filtertyp
Alles löschen
Alle erweitern
öffne alles
Title
-
Tekst na levi
-
Tekst na levi
-
Tekst na levi
-
Tekst na levi
-
Tekst na levi
Več...
Tesfd fsf sdf sdf sdf | |
Tesfd fsf sdf sdf sdf | |
Tesfd fsf sdf sdf sdf |
Title
Tesfd fsf sdf sdf sdf | |
Tesfd fsf sdf sdf sdf | |
Tesfd fsf sdf sdf sdf |
Programmtyp
Aktuelles Programm (221)
Oproduktebsoletes Programm (193)
VVC
Items:
0
{"records":[{"ID":"53424","eti_code":"004220508","descr":"VVC3 7,2kV\/16A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 16A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220508|Fuse link, VVC3 7,2kV\/16A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/16A 2|Rated current 16A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 13.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 56A|Cold resistance 44m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 16A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 16A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"16","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220508-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-16a-7200"},{"ID":"53385","eti_code":"004220003","descr":"VVC3 7,2kV\/2A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 2A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220003|Fuse link, VVC3 7,2kV\/2A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/2A|Rated current 2A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 4W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 12A|Cold resistance 580m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 2A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 2A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"2","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":"","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220003-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-2a-7200"},{"ID":"53610","eti_code":"004230619","descr":"VVC3 12kV\/160A 537","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 537 160A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"6.75","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6993_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004230619|Fuse link, VVC3 12kV\/160A 537|VV|High voltage fuse-links|12 kV|537 mm|537 mm|VVC|Fuse links for medium voltage|VVC|VVC3 12KV\/160A 5|Rated current 160A|Type NEW VVC 50N striker|Size 537|Characteristics Other|Rated AC voltage 12000V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 179W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 600A|Cold resistance 4.1m\u03a9|Fuse link VVC3 NEW VVC 50N striker 537 160A 12000V|Fuse link VVC3 NEW VVC 50N striker 537 160A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"160","type":"NEW VVC 50N striker","size":"537","rated_ac_voltage":"12000","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":"","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004230619-sicherungseinsatz-vvc3-new-vvc-50n-striker-537-160a-12000"},{"ID":"53611","eti_code":"004230620","descr":"VVC3 12kV\/200A 537","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 537 200A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"6.75","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6993_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004230620|Fuse link, VVC3 12kV\/200A 537|VV|High voltage fuse-links|12 kV|537 mm|537 mm|VVC|Fuse links for medium voltage|VVC|VVC3 12KV\/200A 5|Rated current 200A|Type NEW VVC 50N striker|Size 537|Characteristics Other|Rated AC voltage 12000V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 238W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 1000A|Cold resistance 3.3m\u03a9|Fuse link VVC3 NEW VVC 50N striker 537 200A 12000V|Fuse link VVC3 NEW VVC 50N striker 537 200A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"200","type":"NEW VVC 50N striker","size":"537","rated_ac_voltage":"12000","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":"","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004230620-sicherungseinsatz-vvc3-new-vvc-50n-striker-537-200a-12000"},{"ID":"53386","eti_code":"004220004","descr":"VVC3 7,2kV\/4A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 4A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220004|Fuse link, VVC3 7,2kV\/4A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/4A|Rated current 4A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 9W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 20A|Cold resistance 370m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 4A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 4A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"4","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220004-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-4a-7200"},{"ID":"53387","eti_code":"004220005","descr":"VVC3 7,2kV\/6A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 6A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220005|Fuse link, VVC3 7,2kV\/6A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/6A|Rated current 6A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 10W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 25A|Cold resistance 260m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 6A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 6A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"6","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220005-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-6a-7200"},{"ID":"53388","eti_code":"004220006","descr":"VVC3 7,2kV\/6,3A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 6.3A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220006|Fuse link, VVC3 7,2kV\/6,3A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/6,3A|Rated current 6.3A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 10W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 25A|Cold resistance 260m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 6.3A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 6.3A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"6.3","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220006-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-6-3a-7200"},{"ID":"53389","eti_code":"004220007","descr":"VVC3 7,2kV\/10A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 10A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220007|Fuse link, VVC3 7,2kV\/10A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/10A|Rated current 10A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 9W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 43A|Cold resistance 75m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 10A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 10A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"10","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220007-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-10a-7200"},{"ID":"53390","eti_code":"004220008","descr":"VVC3 7,2kV\/16A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 16A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220008|Fuse link, VVC3 7,2kV\/16A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/16A|Rated current 16A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 13.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 56A|Cold resistance 44m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 16A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 16A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"16","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220008-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-16a-7200"},{"ID":"53391","eti_code":"004220009","descr":"VVC3 7,2kV\/20A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 20A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220009|Fuse link, VVC3 7,2kV\/20A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/20A|Rated current 20A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 12.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 70A|Cold resistance 27m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 20A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 20A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"20","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220009-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-20a-7200"},{"ID":"53392","eti_code":"004220010","descr":"VVC3 7,2kV\/25A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 25A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220010|Fuse link, VVC3 7,2kV\/25A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/25A|Rated current 25A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 16W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 87A|Cold resistance 21m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 25A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 25A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"25","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220010-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-25a-7200"},{"ID":"53393","eti_code":"004220011","descr":"VVC3 7,2kV\/31,5A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 31.5A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220011|Fuse link, VVC3 7,2kV\/31,5A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/31,5A|Rated current 31.5A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 23.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 110A|Cold resistance 18m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 31.5A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 31.5A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"31.5","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220011-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-31-5a-7200"},{"ID":"53394","eti_code":"004220012","descr":"VVC3 7,2kV\/32A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 32A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220012|Fuse link, VVC3 7,2kV\/32A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/32A|Rated current 32A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 25W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 110A|Cold resistance 18m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 32A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 32A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"32","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220012-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-32a-7200"},{"ID":"53395","eti_code":"004220013","descr":"VVC3 7,2kV\/40A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 40A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.2","weight_em":"kg","basic_packaging":"3","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220013|Fuse link, VVC3 7,2kV\/40A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/40A|Rated current 40A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 28.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 140A|Cold resistance 13m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 40A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 40A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"40","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220013-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-40a-7200"},{"ID":"53396","eti_code":"004220014","descr":"VVC3 7,2kV\/50A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 50A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.6","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220014|Fuse link, VVC3 7,2kV\/50A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/50A|Rated current 50A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 35.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 175A|Cold resistance 10.5m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 50A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 50A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"50","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220014-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-50a-7200"},{"ID":"53397","eti_code":"004220015","descr":"VVC3 7,2kV\/63A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 63A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.6","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220015|Fuse link, VVC3 7,2kV\/63A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/63A|Rated current 63A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 42.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 220A|Cold resistance 7.5m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 63A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 63A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"63","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220015-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-63a-7200"},{"ID":"53398","eti_code":"004220016","descr":"VVC3 7,2kV\/80A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 80A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.6","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220016|Fuse link, VVC3 7,2kV\/80A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/80A|Rated current 80A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 59W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 280A|Cold resistance 5.9m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 80A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 80A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"80","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220016-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-80a-7200"},{"ID":"53399","eti_code":"004220017","descr":"VVC3 7,2kV\/100A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 100A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"2.62","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220017|Fuse link, VVC3 7,2kV\/100A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/100A|Rated current 100A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 73W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 360A|Cold resistance 4.8m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 100A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 100A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"100","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220017-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-100a-7200"},{"ID":"53400","eti_code":"004220018","descr":"VVC3 7,2kV\/125A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 125A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"2.62","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220018|Fuse link, VVC3 7,2kV\/125A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/125A|Rated current 125A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 101W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 450A|Cold resistance 3.9m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 125A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 125A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"125","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220018-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-125a-7200"},{"ID":"53401","eti_code":"004220019","descr":"VVC3 7,2kV\/160A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 192 160A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"2.62","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220019|Fuse link, VVC3 7,2kV\/160A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/160A|Rated current 160A|Type NEW VVC 50N striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 144W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 600A|Cold resistance 3m\u03a9|Fuse link VVC3 NEW VVC 50N striker 192 160A 7200V|Fuse link VVC3 NEW VVC 50N striker 192 160A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"160","type":"NEW VVC 50N striker","size":"192","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220019-sicherungseinsatz-vvc3-new-vvc-50n-striker-192-160a-7200"},{"ID":"53419","eti_code":"004220503","descr":"VVC3 7,2kV\/2A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 2A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220503|Fuse link, VVC3 7,2kV\/2A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/2A 29|Rated current 2A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 4W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 12A|Cold resistance 580m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 2A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 2A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"2","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220503-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-2a-7200"},{"ID":"53420","eti_code":"004220504","descr":"VVC3 7,2kV\/4A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 4A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220504|Fuse link, VVC3 7,2kV\/4A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/4A 29|Rated current 4A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 9W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 20A|Cold resistance 370m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 4A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 4A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"4","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220504-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-4a-7200"},{"ID":"53421","eti_code":"004220505","descr":"VVC3 7,2kV\/6A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 6A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220505|Fuse link, VVC3 7,2kV\/6A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/6A 29|Rated current 6A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 10W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 25A|Cold resistance 260m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 6A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 6A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"6","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220505-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-6a-7200"},{"ID":"53422","eti_code":"004220506","descr":"VVC3 7,2kV\/6,3A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 6.3A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220506|Fuse link, VVC3 7,2kV\/6,3A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/6,3A|Rated current 6.3A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 10W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 25A|Cold resistance 260m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 6.3A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 6.3A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"6.3","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220506-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-6-3a-7200"},{"ID":"53423","eti_code":"004220507","descr":"VVC3 7,2kV\/10A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 10A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220507|Fuse link, VVC3 7,2kV\/10A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/10A 2|Rated current 10A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 9W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 43A|Cold resistance 75m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 10A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 10A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"10","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220507-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-10a-7200"},{"ID":"53425","eti_code":"004220509","descr":"VVC3 7,2kV\/20A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 20A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220509|Fuse link, VVC3 7,2kV\/20A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/20A 2|Rated current 20A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 12.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 70A|Cold resistance 27m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 20A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 20A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"20","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220509-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-20a-7200"},{"ID":"53426","eti_code":"004220510","descr":"VVC3 7,2kV\/25A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 25A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220510|Fuse link, VVC3 7,2kV\/25A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/25A 2|Rated current 25A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 16W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 87A|Cold resistance 21m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 25A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 25A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"25","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220510-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-25a-7200"},{"ID":"53427","eti_code":"004220511","descr":"VVC3 7,2kV\/31,5A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 31.5A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220511|Fuse link, VVC3 7,2kV\/31,5A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/31,5A|Rated current 31.5A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 23.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 110A|Cold resistance 18m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 31.5A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 31.5A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"31.5","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220511-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-31-5a-7200"},{"ID":"53428","eti_code":"004220512","descr":"VVC3 7,2kV\/32A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 32A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220512|Fuse link, VVC3 7,2kV\/32A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/32A 2|Rated current 32A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 25W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 110A|Cold resistance 18m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 32A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 32A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"32","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220512-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-32a-7200"},{"ID":"53429","eti_code":"004220513","descr":"VVC3 7,2kV\/40A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 40A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220513|Fuse link, VVC3 7,2kV\/40A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/40A 2|Rated current 40A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 28.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 140A|Cold resistance 13m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 40A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 40A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"40","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220513-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-40a-7200"},{"ID":"53430","eti_code":"004220514","descr":"VVC3 7,2kV\/50A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 50A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220514|Fuse link, VVC3 7,2kV\/50A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/50A 2|Rated current 50A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 35.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 175A|Cold resistance 10.5m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 50A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 50A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"50","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220514-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-50a-7200"},{"ID":"53431","eti_code":"004220515","descr":"VVC3 7,2kV\/63A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 63A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"2.8","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220515|Fuse link, VVC3 7,2kV\/63A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/63A 2|Rated current 63A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 42.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 220A|Cold resistance 7.5m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 63A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 63A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"63","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220515-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-63a-7200"},{"ID":"53432","eti_code":"004220516","descr":"VVC3 7,2kV\/80A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 80A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"2.8","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220516|Fuse link, VVC3 7,2kV\/80A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/80A 2|Rated current 80A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 59W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 280A|Cold resistance 5.9m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 80A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 80A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"80","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220516-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-80a-7200"},{"ID":"53433","eti_code":"004220517","descr":"VVC3 7,2kV\/100A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 100A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"2.8","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220517|Fuse link, VVC3 7,2kV\/100A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/100A|Rated current 100A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 73W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 360A|Cold resistance 4.8m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 100A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 100A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"100","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220517-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-100a-7200"},{"ID":"53434","eti_code":"004220518","descr":"VVC3 7,2kV\/125A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 125A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"3.8","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220518|Fuse link, VVC3 7,2kV\/125A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/125A|Rated current 125A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 101W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 450A|Cold resistance 3.9m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 125A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 125A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"125","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220518-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-125a-7200"},{"ID":"53435","eti_code":"004220519","descr":"VVC3 7,2kV\/160A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 160A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"3.8","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220519|Fuse link, VVC3 7,2kV\/160A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/160A|Rated current 160A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 144W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 600A|Cold resistance 3m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 160A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 160A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"160","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220519-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-160a-7200"},{"ID":"53436","eti_code":"004220520","descr":"VVC3 7,2kV\/200A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 200A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"3.8","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220520|Fuse link, VVC3 7,2kV\/200A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/200A|Rated current 200A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 155W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 1000A|Cold resistance 2.1m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 200A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 200A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"200","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220520-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-200a-7200"},{"ID":"53437","eti_code":"004220521","descr":"VVC3 7,2kV\/250A 292","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 292 250A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"3.8","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6971_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220521|Fuse link, VVC3 7,2kV\/250A 292|VV|High voltage fuse-links|7,2 kV|292 mm|292 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/250A|Rated current 250A|Type NEW VVC 50N striker|Size 292|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 196W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 1250A|Cold resistance 1.7m\u03a9|Fuse link VVC3 NEW VVC 50N striker 292 250A 7200V|Fuse link VVC3 NEW VVC 50N striker 292 250A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"250","type":"NEW VVC 50N striker","size":"292","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220521-sicherungseinsatz-vvc3-new-vvc-50n-striker-292-250a-7200"},{"ID":"53457","eti_code":"004220603","descr":"VVC3 7,2kV\/2A 442","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 442 2A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"2.4","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6976_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220603|Fuse link, VVC3 7,2kV\/2A 442|VV|High voltage fuse-links|7,2 kV|442 mm|442 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/2A 44|Rated current 2A|Type NEW VVC 50N striker|Size 442|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 4.7W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 12A|Cold resistance 840m\u03a9|Fuse link VVC3 NEW VVC 50N striker 442 2A 7200V|Fuse link VVC3 NEW VVC 50N striker 442 2A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"2","type":"NEW VVC 50N striker","size":"442","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220603-sicherungseinsatz-vvc3-new-vvc-50n-striker-442-2a-7200"},{"ID":"53458","eti_code":"004220604","descr":"VVC3 7,2kV\/4A 442","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVC3 NEW VVC 50N striker 442 4A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"265","weight":"2.4","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6976_photo.jpg","tree_depth":"2","tree_title":"VVC","program_type":"1","pim_status":"","searchstring":"|004220604|Fuse link, VVC3 7,2kV\/4A 442|VV|High voltage fuse-links|7,2 kV|442 mm|442 mm|VVC|Fuse links for medium voltage|VVC|VVC3 7,2KV\/4A 44|Rated current 4A|Type NEW VVC 50N striker|Size 442|Characteristics Other|Rated AC voltage 7200V|Indicator 50N striker force|Breaking capacity AC 63kA|Power dissipation 11.7W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 20A|Cold resistance 530m\u03a9|Fuse link VVC3 NEW VVC 50N striker 442 4A 7200V|Fuse link VVC3 NEW VVC 50N striker 442 4A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"4","type":"NEW VVC 50N striker","size":"442","rated_ac_voltage":"7200","indicator":"50N striker force","breaking_capacity_ac":"63","Standards":null,"price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004220604-sicherungseinsatz-vvc3-new-vvc-50n-striker-442-4a-7200"}],"columns":[{"name":"eti_code","title":"ETI Artikel-Nummer ","primary":true},{"name":"descr","title":"Beschreibung","primary":false},{"name":"class_name","title":"Klassifizierungsname","primary":false},{"name":"type","title":"Typ","primary":false},{"name":"Price","title":"Preis","cssClass":"price align-right","primary":false},{"name":"StockStatus","title":"Verf\u00fcgbarkeit","primary":false},{"name":"Commands","title":"","primary":false}],"recordsCount":40,"recordsTotalCount":221,"params":{"filters":{"lang":"de-DE","levelId":265,"status":null,"search":null,"programType":"actual"},"pageNumber":1,"pageSize":40,"pageMax":6,"dataEx":{"filterItems":{"type":{"field":"type","values":[{"count":"219","value":"NEW VVC 50N striker"}],"trans":"Typ"},"size":{"field":"size","values":[{"count":"29","value":"192"},{"count":"64","value":"292"},{"count":"17","value":"367"},{"count":"76","value":"442"},{"count":"33","value":"537"}],"trans":"Gr\u00f6\u00dfe"},"rated_current":{"field":"rated_current","values":[{"count":"14","value":"2"},{"count":"14","value":"4"},{"count":"14","value":"6"},{"count":"14","value":"6.3"},{"count":"14","value":"10"},{"count":"14","value":"16"},{"count":"14","value":"20"},{"count":"14","value":"25"},{"count":"13","value":"31.5"},{"count":"13","value":"32"},{"count":"13","value":"40"},{"count":"13","value":"50"},{"count":"12","value":"63"},{"count":"11","value":"80"},{"count":"10","value":"100"},{"count":"9","value":"125"},{"count":"8","value":"160"},{"count":"4","value":"200"},{"count":"2","value":"250"},{"count":"1","value":"315"}],"trans":"Bemessungsstrom (A)"},"rated_ac_voltage":{"field":"rated_ac_voltage","values":[{"count":"56","value":"7200"},{"count":"49","value":"12000"},{"count":"48","value":"17500"},{"count":"46","value":"24000"},{"count":"20","value":"36000"}],"trans":"Bemessungsspannung AC"}},"columnsThumbs":[{"column":"class_name","title":"Klassifizierungsname"},{"column":"type","title":"Typ"},{"column":"size","title":"Gr\u00f6\u00dfe"},{"column":"rated_current","title":"Bemessungsstrom (A)"},{"column":"rated_ac_voltage","title":"Bemessungsspannung AC"}],"columnsThumbsAll":[{"column":"class_name","title":"Klassifizierungsname"},{"column":"type","title":"Typ"},{"column":"size","title":"Gr\u00f6\u00dfe"},{"column":"rated_current","title":"Bemessungsstrom (A)"},{"column":"rated_ac_voltage","title":"Bemessungsspannung AC"},{"column":"breaking_capacity_ac","title":"Abschaltleistung AC"},{"column":"indicator","title":"Anzeiger"},{"column":"Standards","title":"Standard"}],"programTypes":[{"program_type":"0","Count":"193"},{"program_type":"1","Count":"221"}]}}}