VVA

Items: 0
004221102
VVA3 7,2kV/1A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 1
Typ: NEW VVA without striker
Standard:
Größe: 192
004221103
VVA3 7,2kV/2A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 2
Typ: NEW VVA without striker
Standard:
Größe: 192
004221104
VVA3 7,2kV/4A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 4
Typ: NEW VVA without striker
Standard:
Größe: 192
004221105
VVA3 7,2kV/6A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 6
Typ: NEW VVA without striker
Standard:
Größe: 192
004221106
VVA3 7,2kV/6,3A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 6.3
Typ: NEW VVA without striker
Standard:
Größe: 192
004221107
VVA3 7,2kV/10A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 10
Typ: NEW VVA without striker
Standard:
Größe: 192
004221108
VVA3 7,2kV/16A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 16
Typ: NEW VVA without striker
Standard:
Größe: 192
004221109
VVA3 7,2kV/20A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 20
Typ: NEW VVA without striker
Standard:
Größe: 192
004221110
VVA3 7,2kV/25A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 25
Typ: NEW VVA without striker
Standard:
Größe: 192
004221111
VVA3 7,2kV/31,5A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 31.5
Typ: NEW VVA without striker
Standard:
Größe: 192
004221112
VVA3 7,2kV/32A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 32
Typ: NEW VVA without striker
Standard:
Größe: 192
004221113
VVA3 7,2kV/40A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 40
Typ: NEW VVA without striker
Standard:
Größe: 192
004221114
VVA3 7,2kV/50A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 50
Typ: NEW VVA without striker
Standard:
Größe: 192
004221115
VVA3 7,2kV/63A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 63
Typ: NEW VVA without striker
Standard:
Größe: 192
004221116
VVA3 7,2kV/80A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 80
Typ: NEW VVA without striker
Standard:
Größe: 192
004221117
VVA3 7,2kV/100A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 100
Typ: NEW VVA without striker
Standard:
Größe: 192
004221118
VVA3 7,2kV/125A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 125
Typ: NEW VVA without striker
Standard:
Größe: 192
004221119
VVA3 7,2kV/160A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 160
Typ: NEW VVA without striker
Standard:
Größe: 192
004231102
VVA3 12kV/1A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 1
Typ: NEW VVA without striker
Standard:
Größe: 292
004231103
VVA3 12kV/2A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 2
Typ: NEW VVA without striker
Standard:
Größe: 292
004231104
VVA3 12kV/4A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 4
Typ: NEW VVA without striker
Standard:
Größe: 292
004231105
VVA3 12kV/6A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 6
Typ: NEW VVA without striker
Standard:
Größe: 292
004231106
VVA3 12kV/6,3A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 6.3
Typ: NEW VVA without striker
Standard:
Größe: 292
004231107
VVA3 12kV/10A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 10
Typ: NEW VVA without striker
Standard:
Größe: 292
004231108
VVA3 12kV/16A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 16
Typ: NEW VVA without striker
Standard:
Größe: 292
004231109
VVA3 12kV/20A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 20
Typ: NEW VVA without striker
Standard:
Größe: 292
004231110
VVA3 12kV/25A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 25
Typ: NEW VVA without striker
Standard:
Größe: 292
004231111
VVA3 12kV/31,5A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 31.5
Typ: NEW VVA without striker
Standard:
Größe: 292
004231112
VVA3 12kV/32A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 32
Typ: NEW VVA without striker
Standard:
Größe: 292
004231113
VVA3 12kV/40A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 40
Typ: NEW VVA without striker
Standard:
Größe: 292
004231114
VVA3 12kV/50A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 50
Typ: NEW VVA without striker
Standard:
Größe: 292
004231115
VVA3 12kV/63A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 63
Typ: NEW VVA without striker
Standard:
Größe: 292
004231116
VVA3 12kV/80A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 80
Typ: NEW VVA without striker
Standard:
Größe: 292
004231117
VVA3 12kV/100A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 100
Typ: NEW VVA without striker
Standard:
Größe: 292
004231118
VVA3 12kV/125A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 125
Typ: NEW VVA without striker
Standard:
Größe: 292
004231119
VVA3 12kV/160A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 160
Typ: NEW VVA without striker
Standard:
Größe: 292
004241102
VVA3 17,5kV/1A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 1
Typ: NEW VVA without striker
Standard:
Größe: 367
004241103
VVA3 17,5kV/2A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 2
Typ: NEW VVA without striker
Standard:
Größe: 367
004241104
VVA3 17,5kV/4A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 4
Typ: NEW VVA without striker
Standard:
Größe: 367
004241105
VVA3 17,5kV/6A
Klassifizierungsname: Sicherungseinsatz
Bemessungsstrom (A): 6
Typ: NEW VVA without striker
Standard:
Größe: 367
{"records":[{"ID":"53367","eti_code":"004221102","descr":"VVA3 7,2kV\/1A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 1A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221102|Fuse link, VVA3 7,2kV\/1A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/1A|Rated current 1A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 3W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 12A|Cold resistance 1170m\u03a9|Fuse link VVA3 NEW VVA without striker 192 1A 7200V|Fuse link VVA3 NEW VVA without striker 192 1A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"1","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221102-sicherungseinsatz-vva3-new-vva-without-striker-192-1a-7200"},{"ID":"53368","eti_code":"004221103","descr":"VVA3 7,2kV\/2A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 2A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221103|Fuse link, VVA3 7,2kV\/2A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/2A|Rated current 2A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 4W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 12A|Cold resistance 580m\u03a9|Fuse link VVA3 NEW VVA without striker 192 2A 7200V|Fuse link VVA3 NEW VVA without striker 192 2A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"2","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221103-sicherungseinsatz-vva3-new-vva-without-striker-192-2a-7200"},{"ID":"53369","eti_code":"004221104","descr":"VVA3 7,2kV\/4A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 4A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221104|Fuse link, VVA3 7,2kV\/4A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/4A|Rated current 4A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 9W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 20A|Cold resistance 370m\u03a9|Fuse link VVA3 NEW VVA without striker 192 4A 7200V|Fuse link VVA3 NEW VVA without striker 192 4A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"4","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221104-sicherungseinsatz-vva3-new-vva-without-striker-192-4a-7200"},{"ID":"53370","eti_code":"004221105","descr":"VVA3 7,2kV\/6A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 6A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221105|Fuse link, VVA3 7,2kV\/6A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/6A|Rated current 6A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 10W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 25A|Cold resistance 260m\u03a9|Fuse link VVA3 NEW VVA without striker 192 6A 7200V|Fuse link VVA3 NEW VVA without striker 192 6A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"6","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221105-sicherungseinsatz-vva3-new-vva-without-striker-192-6a-7200"},{"ID":"53371","eti_code":"004221106","descr":"VVA3 7,2kV\/6,3A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 6.3A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221106|Fuse link, VVA3 7,2kV\/6,3A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/6,3A|Rated current 6.3A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 10W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 25A|Cold resistance 260m\u03a9|Fuse link VVA3 NEW VVA without striker 192 6.3A 7200V|Fuse link VVA3 NEW VVA without striker 192 6.3A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"6.3","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221106-sicherungseinsatz-vva3-new-vva-without-striker-192-6-3a-7200"},{"ID":"53372","eti_code":"004221107","descr":"VVA3 7,2kV\/10A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 10A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221107|Fuse link, VVA3 7,2kV\/10A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/10A|Rated current 10A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 9W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 43A|Cold resistance 75m\u03a9|Fuse link VVA3 NEW VVA without striker 192 10A 7200V|Fuse link VVA3 NEW VVA without striker 192 10A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"10","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221107-sicherungseinsatz-vva3-new-vva-without-striker-192-10a-7200"},{"ID":"53373","eti_code":"004221108","descr":"VVA3 7,2kV\/16A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 16A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221108|Fuse link, VVA3 7,2kV\/16A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/16A|Rated current 16A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 13.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 56A|Cold resistance 44m\u03a9|Fuse link VVA3 NEW VVA without striker 192 16A 7200V|Fuse link VVA3 NEW VVA without striker 192 16A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"16","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221108-sicherungseinsatz-vva3-new-vva-without-striker-192-16a-7200"},{"ID":"53374","eti_code":"004221109","descr":"VVA3 7,2kV\/20A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 20A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221109|Fuse link, VVA3 7,2kV\/20A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/20A|Rated current 20A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 12.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 70A|Cold resistance 27m\u03a9|Fuse link VVA3 NEW VVA without striker 192 20A 7200V|Fuse link VVA3 NEW VVA without striker 192 20A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"20","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221109-sicherungseinsatz-vva3-new-vva-without-striker-192-20a-7200"},{"ID":"53375","eti_code":"004221110","descr":"VVA3 7,2kV\/25A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 25A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221110|Fuse link, VVA3 7,2kV\/25A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/25A|Rated current 25A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 16W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 87A|Cold resistance 21m\u03a9|Fuse link VVA3 NEW VVA without striker 192 25A 7200V|Fuse link VVA3 NEW VVA without striker 192 25A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"25","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221110-sicherungseinsatz-vva3-new-vva-without-striker-192-25a-7200"},{"ID":"53376","eti_code":"004221111","descr":"VVA3 7,2kV\/31,5A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 31.5A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221111|Fuse link, VVA3 7,2kV\/31,5A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/31,5A|Rated current 31.5A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 23.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 110A|Cold resistance 18m\u03a9|Fuse link VVA3 NEW VVA without striker 192 31.5A 7200V|Fuse link VVA3 NEW VVA without striker 192 31.5A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"31.5","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221111-sicherungseinsatz-vva3-new-vva-without-striker-192-31-5a-7200"},{"ID":"53377","eti_code":"004221112","descr":"VVA3 7,2kV\/32A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 32A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221112|Fuse link, VVA3 7,2kV\/32A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/32A|Rated current 32A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 25W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 110A|Cold resistance 18m\u03a9|Fuse link VVA3 NEW VVA without striker 192 32A 7200V|Fuse link VVA3 NEW VVA without striker 192 32A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"32","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221112-sicherungseinsatz-vva3-new-vva-without-striker-192-32a-7200"},{"ID":"53378","eti_code":"004221113","descr":"VVA3 7,2kV\/40A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 40A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221113|Fuse link, VVA3 7,2kV\/40A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/40A|Rated current 40A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 28.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 140A|Cold resistance 13m\u03a9|Fuse link VVA3 NEW VVA without striker 192 40A 7200V|Fuse link VVA3 NEW VVA without striker 192 40A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"40","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221113-sicherungseinsatz-vva3-new-vva-without-striker-192-40a-7200"},{"ID":"53379","eti_code":"004221114","descr":"VVA3 7,2kV\/50A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 50A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.6","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221114|Fuse link, VVA3 7,2kV\/50A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/50A|Rated current 50A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 35.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 175A|Cold resistance 10.5m\u03a9|Fuse link VVA3 NEW VVA without striker 192 50A 7200V|Fuse link VVA3 NEW VVA without striker 192 50A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"50","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221114-sicherungseinsatz-vva3-new-vva-without-striker-192-50a-7200"},{"ID":"53380","eti_code":"004221115","descr":"VVA3 7,2kV\/63A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 63A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.6","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221115|Fuse link, VVA3 7,2kV\/63A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/63A|Rated current 63A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 42.5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 220A|Cold resistance 7.5m\u03a9|Fuse link VVA3 NEW VVA without striker 192 63A 7200V|Fuse link VVA3 NEW VVA without striker 192 63A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"63","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221115-sicherungseinsatz-vva3-new-vva-without-striker-192-63a-7200"},{"ID":"53381","eti_code":"004221116","descr":"VVA3 7,2kV\/80A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 80A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.6","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221116|Fuse link, VVA3 7,2kV\/80A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/80A|Rated current 80A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 59W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 280A|Cold resistance 5.9m\u03a9|Fuse link VVA3 NEW VVA without striker 192 80A 7200V|Fuse link VVA3 NEW VVA without striker 192 80A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"80","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221116-sicherungseinsatz-vva3-new-vva-without-striker-192-80a-7200"},{"ID":"53382","eti_code":"004221117","descr":"VVA3 7,2kV\/100A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 100A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"2.62","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221117|Fuse link, VVA3 7,2kV\/100A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/100A|Rated current 100A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 73W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 360A|Cold resistance 4.8m\u03a9|Fuse link VVA3 NEW VVA without striker 192 100A 7200V|Fuse link VVA3 NEW VVA without striker 192 100A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"100","size":"192","Standards":"","type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221117-sicherungseinsatz-vva3-new-vva-without-striker-192-100a-7200"},{"ID":"53383","eti_code":"004221118","descr":"VVA3 7,2kV\/125A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 125A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"2.62","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221118|Fuse link, VVA3 7,2kV\/125A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/125A|Rated current 125A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 101W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 450A|Cold resistance 3.9m\u03a9|Fuse link VVA3 NEW VVA without striker 192 125A 7200V|Fuse link VVA3 NEW VVA without striker 192 125A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"125","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221118-sicherungseinsatz-vva3-new-vva-without-striker-192-125a-7200"},{"ID":"53384","eti_code":"004221119","descr":"VVA3 7,2kV\/160A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 192 160A 7200","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"2.62","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6954_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004221119|Fuse link, VVA3 7,2kV\/160A|VV|High voltage fuse-links|7,2 kV|192 mm|192 mm|VVA|Fuse links for medium voltage|VVA|VVA3 7,2KV\/160A|Rated current 160A|Type NEW VVA without striker|Size 192|Characteristics Other|Rated AC voltage 7200V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 144W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 600A|Cold resistance 3m\u03a9|Fuse link VVA3 NEW VVA without striker 192 160A 7200V|Fuse link VVA3 NEW VVA without striker 192 160A 7200V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"7200","rated_current":"160","size":"192","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004221119-sicherungseinsatz-vva3-new-vva-without-striker-192-160a-7200"},{"ID":"53522","eti_code":"004231102","descr":"VVA3 12kV\/1A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 1A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231102|Fuse link, VVA3 12kV\/1A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/1A|Rated current 1A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 5W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 12A|Cold resistance 1970m\u03a9|Fuse link VVA3 NEW VVA without striker 292 1A 12000V|Fuse link VVA3 NEW VVA without striker 292 1A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"1","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231102-sicherungseinsatz-vva3-new-vva-without-striker-292-1a-12000"},{"ID":"53523","eti_code":"004231103","descr":"VVA3 12kV\/2A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 2A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231103|Fuse link, VVA3 12kV\/2A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/2A|Rated current 2A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 6W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 12A|Cold resistance 980m\u03a9|Fuse link VVA3 NEW VVA without striker 292 2A 12000V|Fuse link VVA3 NEW VVA without striker 292 2A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"2","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231103-sicherungseinsatz-vva3-new-vva-without-striker-292-2a-12000"},{"ID":"53524","eti_code":"004231104","descr":"VVA3 12kV\/4A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 4A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231104|Fuse link, VVA3 12kV\/4A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/4A|Rated current 4A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 15W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 20A|Cold resistance 650m\u03a9|Fuse link VVA3 NEW VVA without striker 292 4A 12000V|Fuse link VVA3 NEW VVA without striker 292 4A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"4","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231104-sicherungseinsatz-vva3-new-vva-without-striker-292-4a-12000"},{"ID":"53525","eti_code":"004231105","descr":"VVA3 12kV\/6A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 6A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231105|Fuse link, VVA3 12kV\/6A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/6A|Rated current 6A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 21W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 25A|Cold resistance 435m\u03a9|Fuse link VVA3 NEW VVA without striker 292 6A 12000V|Fuse link VVA3 NEW VVA without striker 292 6A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"6","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231105-sicherungseinsatz-vva3-new-vva-without-striker-292-6a-12000"},{"ID":"53526","eti_code":"004231106","descr":"VVA3 12kV\/6,3A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 6.3A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231106|Fuse link, VVA3 12kV\/6,3A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/6,3A|Rated current 6.3A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 21W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 25A|Cold resistance 435m\u03a9|Fuse link VVA3 NEW VVA without striker 292 6.3A 12000V|Fuse link VVA3 NEW VVA without striker 292 6.3A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"6.3","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231106-sicherungseinsatz-vva3-new-vva-without-striker-292-6-3a-12000"},{"ID":"53527","eti_code":"004231107","descr":"VVA3 12kV\/10A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 10A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231107|Fuse link, VVA3 12kV\/10A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/10A|Rated current 10A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 15W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 43A|Cold resistance 130m\u03a9|Fuse link VVA3 NEW VVA without striker 292 10A 12000V|Fuse link VVA3 NEW VVA without striker 292 10A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"10","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231107-sicherungseinsatz-vva3-new-vva-without-striker-292-10a-12000"},{"ID":"53528","eti_code":"004231108","descr":"VVA3 12kV\/16A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 16A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231108|Fuse link, VVA3 12kV\/16A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/16A|Rated current 16A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 23W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 56A|Cold resistance 70m\u03a9|Fuse link VVA3 NEW VVA without striker 292 16A 12000V|Fuse link VVA3 NEW VVA without striker 292 16A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"16","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231108-sicherungseinsatz-vva3-new-vva-without-striker-292-16a-12000"},{"ID":"53529","eti_code":"004231109","descr":"VVA3 12kV\/20A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 20A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231109|Fuse link, VVA3 12kV\/20A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/20A|Rated current 20A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 21W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 70A|Cold resistance 44m\u03a9|Fuse link VVA3 NEW VVA without striker 292 20A 12000V|Fuse link VVA3 NEW VVA without striker 292 20A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"20","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231109-sicherungseinsatz-vva3-new-vva-without-striker-292-20a-12000"},{"ID":"53530","eti_code":"004231110","descr":"VVA3 12kV\/25A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 25A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231110|Fuse link, VVA3 12kV\/25A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/25A|Rated current 25A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 28W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 87A|Cold resistance 33m\u03a9|Fuse link VVA3 NEW VVA without striker 292 25A 12000V|Fuse link VVA3 NEW VVA without striker 292 25A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"25","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231110-sicherungseinsatz-vva3-new-vva-without-striker-292-25a-12000"},{"ID":"53531","eti_code":"004231111","descr":"VVA3 12kV\/31,5A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 31.5A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231111|Fuse link, VVA3 12kV\/31,5A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/31,5A|Rated current 31.5A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 38W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 110A|Cold resistance 29m\u03a9|Fuse link VVA3 NEW VVA without striker 292 31.5A 12000V|Fuse link VVA3 NEW VVA without striker 292 31.5A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"31.5","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231111-sicherungseinsatz-vva3-new-vva-without-striker-292-31-5a-12000"},{"ID":"53532","eti_code":"004231112","descr":"VVA3 12kV\/32A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 32A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231112|Fuse link, VVA3 12kV\/32A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/32A|Rated current 32A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 41W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 110A|Cold resistance 29m\u03a9|Fuse link VVA3 NEW VVA without striker 292 32A 12000V|Fuse link VVA3 NEW VVA without striker 292 32A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"32","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231112-sicherungseinsatz-vva3-new-vva-without-striker-292-32a-12000"},{"ID":"53533","eti_code":"004231113","descr":"VVA3 12kV\/40A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 40A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"1.7","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231113|Fuse link, VVA3 12kV\/40A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/40A|Rated current 40A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 48W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 140A|Cold resistance 21m\u03a9|Fuse link VVA3 NEW VVA without striker 292 40A 12000V|Fuse link VVA3 NEW VVA without striker 292 40A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"40","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231113-sicherungseinsatz-vva3-new-vva-without-striker-292-40a-12000"},{"ID":"53534","eti_code":"004231114","descr":"VVA3 12kV\/50A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 50A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"2.8","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231114|Fuse link, VVA3 12kV\/50A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/50A|Rated current 50A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 54W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 175A|Cold resistance 16.5m\u03a9|Fuse link VVA3 NEW VVA without striker 292 50A 12000V|Fuse link VVA3 NEW VVA without striker 292 50A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"50","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231114-sicherungseinsatz-vva3-new-vva-without-striker-292-50a-12000"},{"ID":"53535","eti_code":"004231115","descr":"VVA3 12kV\/63A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 63A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"2.8","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231115|Fuse link, VVA3 12kV\/63A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/63A|Rated current 63A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 62W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 220A|Cold resistance 12m\u03a9|Fuse link VVA3 NEW VVA without striker 292 63A 12000V|Fuse link VVA3 NEW VVA without striker 292 63A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"63","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231115-sicherungseinsatz-vva3-new-vva-without-striker-292-63a-12000"},{"ID":"53536","eti_code":"004231116","descr":"VVA3 12kV\/80A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 80A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"2.8","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231116|Fuse link, VVA3 12kV\/80A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/80A|Rated current 80A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 75W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 280A|Cold resistance 9m\u03a9|Fuse link VVA3 NEW VVA without striker 292 80A 12000V|Fuse link VVA3 NEW VVA without striker 292 80A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"80","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231116-sicherungseinsatz-vva3-new-vva-without-striker-292-80a-12000"},{"ID":"53537","eti_code":"004231117","descr":"VVA3 12kV\/100A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 100A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"3.8","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231117|Fuse link, VVA3 12kV\/100A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/100A|Rated current 100A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 114W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 360A|Cold resistance 6.7m\u03a9|Fuse link VVA3 NEW VVA without striker 292 100A 12000V|Fuse link VVA3 NEW VVA without striker 292 100A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"100","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231117-sicherungseinsatz-vva3-new-vva-without-striker-292-100a-12000"},{"ID":"53538","eti_code":"004231118","descr":"VVA3 12kV\/125A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 125A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"3.8","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231118|Fuse link, VVA3 12kV\/125A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/125A|Rated current 125A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 138W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 450A|Cold resistance 5.2m\u03a9|Fuse link VVA3 NEW VVA without striker 292 125A 12000V|Fuse link VVA3 NEW VVA without striker 292 125A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"125","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231118-sicherungseinsatz-vva3-new-vva-without-striker-292-125a-12000"},{"ID":"53539","eti_code":"004231119","descr":"VVA3 12kV\/160A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 292 160A 12000","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"3.8","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6983_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004231119|Fuse link, VVA3 12kV\/160A|VV|High voltage fuse-links|12 kV|292 mm|292 mm|VVA|Fuse links for medium voltage|VVA|VVA3 12KV\/160A|Rated current 160A|Type NEW VVA without striker|Size 292|Characteristics Other|Rated AC voltage 12000V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 179W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 600A|Cold resistance 4.1m\u03a9|Fuse link VVA3 NEW VVA without striker 292 160A 12000V|Fuse link VVA3 NEW VVA without striker 292 160A 12000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"12000","rated_current":"160","size":"292","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004231119-sicherungseinsatz-vva3-new-vva-without-striker-292-160a-12000"},{"ID":"53647","eti_code":"004241102","descr":"VVA3 17,5kV\/1A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 367 1A 17500","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/7000_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004241102|Fuse link, VVA3 17,5kV\/1A|VV|High voltage fuse-links|17,5 kV|367 mm|367 mm|VVA|Fuse links for medium voltage|VVA|VVA3 17,5KV\/1A|Rated current 1A|Type NEW VVA without striker|Size 367|Characteristics Other|Rated AC voltage 17500V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 6W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 12A|Cold resistance 2800m\u03a9|Fuse link VVA3 NEW VVA without striker 367 1A 17500V|Fuse link VVA3 NEW VVA without striker 367 1A 17500V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"17500","rated_current":"1","size":"367","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004241102-sicherungseinsatz-vva3-new-vva-without-striker-367-1a-17500"},{"ID":"53648","eti_code":"004241103","descr":"VVA3 17,5kV\/2A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 367 2A 17500","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/7000_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004241103|Fuse link, VVA3 17,5kV\/2A|VV|High voltage fuse-links|17,5 kV|367 mm|367 mm|VVA|Fuse links for medium voltage|VVA|VVA3 17,5KV\/2A|Rated current 2A|Type NEW VVA without striker|Size 367|Characteristics Other|Rated AC voltage 17500V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 8W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 12A|Cold resistance 1400m\u03a9|Fuse link VVA3 NEW VVA without striker 367 2A 17500V|Fuse link VVA3 NEW VVA without striker 367 2A 17500V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"17500","rated_current":"2","size":"367","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004241103-sicherungseinsatz-vva3-new-vva-without-striker-367-2a-17500"},{"ID":"53649","eti_code":"004241104","descr":"VVA3 17,5kV\/4A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 367 4A 17500","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/7000_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004241104|Fuse link, VVA3 17,5kV\/4A|VV|High voltage fuse-links|17,5 kV|367 mm|367 mm|VVA|Fuse links for medium voltage|VVA|VVA3 17,5KV\/4A|Rated current 4A|Type NEW VVA without striker|Size 367|Characteristics Other|Rated AC voltage 17500V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 17W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 20A|Cold resistance 900m\u03a9|Fuse link VVA3 NEW VVA without striker 367 4A 17500V|Fuse link VVA3 NEW VVA without striker 367 4A 17500V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"17500","rated_current":"4","size":"367","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004241104-sicherungseinsatz-vva3-new-vva-without-striker-367-4a-17500"},{"ID":"53650","eti_code":"004241105","descr":"VVA3 17,5kV\/6A","descr_uk_UA":"","descr_uk_RU":"","seo_name":"Sicherungseinsatz VVA3 NEW VVA without striker 367 6A 17500","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"508","weight":"2","weight_em":"kg","basic_packaging":"1","shipping_packaging":"3","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/7000_photo.jpg","tree_depth":"2","tree_title":"VVA","program_type":"1","pim_status":"","searchstring":"|004241105|Fuse link, VVA3 17,5kV\/6A|VV|High voltage fuse-links|17,5 kV|367 mm|367 mm|VVA|Fuse links for medium voltage|VVA|VVA3 17,5KV\/6A|Rated current 6A|Type NEW VVA without striker|Size 367|Characteristics Other|Rated AC voltage 17500V|Indicator Without|Breaking capacity AC 63kA|Power dissipation 35W|Application transformer protection, motor protection, capacitor bank protection, installation in ring main unit|Rated minimum breaking current 25A|Cold resistance 670m\u03a9|Fuse link VVA3 NEW VVA without striker 367 6A 17500V|Fuse link VVA3 NEW VVA without striker 367 6A 17500V|","stockammount":"0","stockstatus":"0","preview_mode":"0","breaking_capacity_ac":"63","indicator":"Without","rated_ac_voltage":"17500","rated_current":"6","size":"367","Standards":null,"type":"NEW VVA without striker","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004241105-sicherungseinsatz-vva3-new-vva-without-striker-367-6a-17500"}],"columns":[{"name":"eti_code","title":"ETI Artikel-Nummer ","primary":true},{"name":"descr","title":"Beschreibung","primary":false},{"name":"class_name","title":"Klassifizierungsname","primary":false},{"name":"rated_current","title":"Bemessungsstrom (A)","primary":false},{"name":"Price","title":"Preis","cssClass":"price align-right","primary":false},{"name":"StockStatus","title":"Verf\u00fcgbarkeit","primary":false},{"name":"Commands","title":"","primary":false}],"recordsCount":40,"recordsTotalCount":86,"params":{"filters":{"lang":"de-DE","levelId":508,"status":null,"search":null,"programType":"actual"},"pageNumber":1,"pageSize":40,"pageMax":3,"dataEx":{"filterItems":{"rated_current":{"field":"rated_current","values":[{"count":"5","value":"1"},{"count":"5","value":"2"},{"count":"5","value":"4"},{"count":"5","value":"6"},{"count":"5","value":"6.3"},{"count":"5","value":"10"},{"count":"5","value":"16"},{"count":"5","value":"20"},{"count":"5","value":"25"},{"count":"5","value":"31.5"},{"count":"5","value":"32"},{"count":"5","value":"40"},{"count":"5","value":"50"},{"count":"5","value":"63"},{"count":"5","value":"80"},{"count":"4","value":"100"},{"count":"4","value":"125"},{"count":"3","value":"160"}],"trans":"Bemessungsstrom (A)"},"type":{"field":"type","values":[{"count":"86","value":"NEW VVA without striker"}],"trans":"Typ"},"size":{"field":"size","values":[{"count":"18","value":"192"},{"count":"18","value":"292"},{"count":"18","value":"367"},{"count":"17","value":"442"},{"count":"15","value":"537"}],"trans":"Gr\u00f6\u00dfe"},"rated_ac_voltage":{"field":"rated_ac_voltage","values":[{"count":"18","value":"7200"},{"count":"18","value":"12000"},{"count":"18","value":"17500"},{"count":"17","value":"24000"},{"count":"15","value":"36000"}],"trans":"Bemessungsspannung AC"}},"columnsThumbs":[{"column":"class_name","title":"Klassifizierungsname"},{"column":"rated_current","title":"Bemessungsstrom (A)"},{"column":"type","title":"Typ"},{"column":"Standards","title":"Standard"},{"column":"size","title":"Gr\u00f6\u00dfe"}],"columnsThumbsAll":[{"column":"class_name","title":"Klassifizierungsname"},{"column":"rated_current","title":"Bemessungsstrom (A)"},{"column":"type","title":"Typ"},{"column":"Standards","title":"Standard"},{"column":"size","title":"Gr\u00f6\u00dfe"},{"column":"rated_ac_voltage","title":"Bemessungsspannung AC"},{"column":"indicator","title":"Anzeiger"},{"column":"breaking_capacity_ac","title":"Abschaltleistung AC"}],"programTypes":{"1":{"program_type":"1","Count":"86"}}}}}