Sicherungseinsätze für Sonderzwecke

Items: 0
004113703
NH1/85 gG 10A/1000V
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 10
Bemessungsspannung AC: 1000
004113704
NH1/85 gG 16A/1000V
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 16
Bemessungsspannung AC: 1000
004113705
NH1/85 gG 20A/1000V
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 20
Bemessungsspannung AC: 1000
004113706
NH1/85 gG 25A/1000V
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 25
Bemessungsspannung AC: 1000
004113707
NH1/85 gG 32A/1000V
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 32
Bemessungsspannung AC: 1000
004113708
NH1/85 gG 35A/1000V
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 35
Bemessungsspannung AC: 1000
004113710
NH1/85 gG 40A/1000V
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 40
Bemessungsspannung AC: 1000
004113711
NH1/85 gG 50A/1000V
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 50
Bemessungsspannung AC: 1000
004113712
NH1/85 gG 63A/1000V
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 63
Bemessungsspannung AC: 1000
004113713
NH1/85 gG 80A/1000V
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 80
Bemessungsspannung AC: 1000
004113714
NH1/85 gG 100A/1000V
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 100
Bemessungsspannung AC: 1000
004113715
NH1/85 gG 125A/1000V
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 125
Bemessungsspannung AC: 1000
004113716
NH1/85 gG 160A/1000V
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 160
Bemessungsspannung AC: 1000
004113717
NH1/85 gG 200A/1000V
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 200
Bemessungsspannung AC: 1000
004723259
NH1 BAT 40A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 40
Bemessungsspannung AC:
004723260
NH1 BAT 50A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 50
Bemessungsspannung AC:
004723261
NH1 BAT 63A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 63
Bemessungsspannung AC:
004723262
NH1 BAT 80A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 80
Bemessungsspannung AC:
004723263
NH1 BAT 100A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 100
Bemessungsspannung AC:
004723264
NH1 BAT 125A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 125
Bemessungsspannung AC:
004723265
NH1 BAT 160A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 160
Bemessungsspannung AC:
004723266
NH1 BAT 200A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 200
Bemessungsspannung AC:
004723267
NH1 BAT 224A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 224
Bemessungsspannung AC:
004723268
NH1 BAT 250A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 250
Bemessungsspannung AC:
004723269
NHS1/110 BAT 40A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 40
Bemessungsspannung AC:
004723270
NHS1/110 BAT 50A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 50
Bemessungsspannung AC:
004723271
NHS1/110 BAT 63A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 63
Bemessungsspannung AC:
004723272
NHS1/110 BAT 80A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 80
Bemessungsspannung AC:
004723273
NHS1/110 BAT 100A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 100
Bemessungsspannung AC:
004723274
NHS1/110 BAT 125A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 125
Bemessungsspannung AC:
004723275
NHS1/110 BAT 160A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 160
Bemessungsspannung AC:
004723276
NHS1/110 BAT 200A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 200
Bemessungsspannung AC:
004723277
NHS1/110 BAT 224A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 224
Bemessungsspannung AC:
004723278
NHS1/110 BAT 250A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 250
Bemessungsspannung AC:
004723279
NH1/K BAT 40A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 40
Bemessungsspannung AC:
004723280
NH1/K BAT 50A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 50
Bemessungsspannung AC:
004723281
NH1/K BAT 63A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 63
Bemessungsspannung AC:
004723282
NH1/K BAT 80A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 80
Bemessungsspannung AC:
004723283
NH1/K BAT 100A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 100
Bemessungsspannung AC:
004723284
NH1/K BAT 125A/550V DC
Klassifizierungsname: Sicherungseinsatz
Typ: NH
Größe: NH1
Bemessungsstrom (A): 125
Bemessungsspannung AC:
{"records":[{"ID":"98","eti_code":"004113703","descr":"NH1\/85 gG 10A\/1000V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/85 NH NH1 10A 1000 gG","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".663","weight_em":"kg","basic_packaging":"3","shipping_packaging":"12","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6146_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004113703|Fuse link, NH1\/85 gG 10A\/1000V|Special fuses|Fuse links gG 1000V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|Mining fuses|NH1\/85 GG 10A\/10|Rated current 10A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 1000V|Indicator Top fuse status indicator|Breaking capacity AC 50kA|Power dissipation 1,9W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269|Application For cable protection|Fuse link NH1\/85 NH NH1 10A 1000V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"10","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"1000","rated_dc_voltage":"","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"50","breaking_capacity_dc":"","pd_w":"1,9","Standards":"IEC 60269","Power_dissip_07":"","Operating_joule":"","Prearcing_joule":"","Application":"zum Kabelschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004113703-sicherungseinsatz-nh1-85-nh-nh1-10a-1000-gg"},{"ID":"3084","eti_code":"004113704","descr":"NH1\/85 gG 16A\/1000V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/85 NH NH1 16A 1000 gG","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".663","weight_em":"kg","basic_packaging":"3","shipping_packaging":"12","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6146_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004113704|Fuse link, NH1\/85 gG 16A\/1000V|Special fuses|Fuse links gG 1000V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|Mining fuses|NH1\/85 GG 16A\/10|Rated current 16A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 1000V|Indicator Top fuse status indicator|Breaking capacity AC 50kA|Power dissipation 3,9W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269|Application For cable protection|Fuse link NH1\/85 NH NH1 16A 1000V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"16","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"1000","rated_dc_voltage":"","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"50","breaking_capacity_dc":"","pd_w":"3,9","Standards":"IEC 60269","Power_dissip_07":"","Operating_joule":"","Prearcing_joule":"","Application":"zum Kabelschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004113704-sicherungseinsatz-nh1-85-nh-nh1-16a-1000-gg"},{"ID":"3085","eti_code":"004113705","descr":"NH1\/85 gG 20A\/1000V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/85 NH NH1 20A 1000 gG","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".663","weight_em":"kg","basic_packaging":"3","shipping_packaging":"12","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6146_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004113705|Fuse link, NH1\/85 gG 20A\/1000V|Special fuses|Fuse links gG 1000V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|Mining fuses|NH1\/85 GG 20A\/10|Rated current 20A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 1000V|Indicator Top fuse status indicator|Breaking capacity AC 50kA|Power dissipation 3,9W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269|Application For cable protection|Fuse link NH1\/85 NH NH1 20A 1000V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"20","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"1000","rated_dc_voltage":"","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"50","breaking_capacity_dc":"","pd_w":"3,9","Standards":"IEC 60269","Power_dissip_07":"","Operating_joule":"","Prearcing_joule":"","Application":"zum Kabelschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004113705-sicherungseinsatz-nh1-85-nh-nh1-20a-1000-gg"},{"ID":"3142","eti_code":"004113706","descr":"NH1\/85 gG 25A\/1000V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/85 NH NH1 25A 1000 gG","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".663","weight_em":"kg","basic_packaging":"3","shipping_packaging":"12","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6146_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004113706|Fuse link, NH1\/85 gG 25A\/1000V|Special fuses|Fuse links gG 1000V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|Mining fuses|NH1\/85 GG 25A\/10|Rated current 25A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 1000V|Indicator Top fuse status indicator|Breaking capacity AC 50kA|Power dissipation 4,3W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269|Application For cable protection|Fuse link NH1\/85 NH NH1 25A 1000V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"25","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"1000","rated_dc_voltage":"","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"50","breaking_capacity_dc":"","pd_w":"4,3","Standards":"IEC 60269","Power_dissip_07":"","Operating_joule":"","Prearcing_joule":"","Application":"zum Kabelschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004113706-sicherungseinsatz-nh1-85-nh-nh1-25a-1000-gg"},{"ID":"32536","eti_code":"004113707","descr":"NH1\/85 gG 32A\/1000V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/85 NH NH1 32A 1000 gG","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".663","weight_em":"kg","basic_packaging":"3","shipping_packaging":"12","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6146_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004113707|Fuse link, NH1\/85 gG 32A\/1000V|Special fuses|Fuse links gG 1000V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|Mining fuses|NH1\/85 GG 32A\/10|Rated current 32A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 1000V|Indicator Top fuse status indicator|Breaking capacity AC 50kA|Power dissipation 3,8W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269|Application For cable protection|Fuse link NH1\/85 NH NH1 32A 1000V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"32","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"1000","rated_dc_voltage":"","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"50","breaking_capacity_dc":"","pd_w":"3,8","Standards":"IEC 60269","Power_dissip_07":"","Operating_joule":"","Prearcing_joule":"","Application":"zum Kabelschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004113707-sicherungseinsatz-nh1-85-nh-nh1-32a-1000-gg"},{"ID":"5370","eti_code":"004113708","descr":"NH1\/85 gG 35A\/1000V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/85 NH NH1 35A 1000 gG","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".663","weight_em":"kg","basic_packaging":"3","shipping_packaging":"12","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6146_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004113708|Fuse link, NH1\/85 gG 35A\/1000V|Special fuses|Fuse links gG 1000V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|Mining fuses|NH1\/85 GG 35A\/10|Rated current 35A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 1000V|Indicator Top fuse status indicator|Breaking capacity AC 50kA|Power dissipation 4,6W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269|Application For cable protection|Fuse link NH1\/85 NH NH1 35A 1000V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"35","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"1000","rated_dc_voltage":"","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"50","breaking_capacity_dc":"","pd_w":"4,6","Standards":"IEC 60269","Power_dissip_07":"","Operating_joule":"","Prearcing_joule":"","Application":"zum Kabelschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004113708-sicherungseinsatz-nh1-85-nh-nh1-35a-1000-gg"},{"ID":"3143","eti_code":"004113710","descr":"NH1\/85 gG 40A\/1000V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/85 NH NH1 40A 1000 gG","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".663","weight_em":"kg","basic_packaging":"3","shipping_packaging":"12","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6146_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004113710|Fuse link, NH1\/85 gG 40A\/1000V|Special fuses|Fuse links gG 1000V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|Mining fuses|NH1\/85 GG 40A\/10|Rated current 40A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 1000V|Indicator Top fuse status indicator|Breaking capacity AC 50kA|Power dissipation 5,5W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269|Application For cable protection|Fuse link NH1\/85 NH NH1 40A 1000V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"40","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"1000","rated_dc_voltage":"","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"50","breaking_capacity_dc":"","pd_w":"5,5","Standards":"IEC 60269","Power_dissip_07":"","Operating_joule":"","Prearcing_joule":"","Application":"zum Kabelschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004113710-sicherungseinsatz-nh1-85-nh-nh1-40a-1000-gg"},{"ID":"5368","eti_code":"004113711","descr":"NH1\/85 gG 50A\/1000V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/85 NH NH1 50A 1000 gG","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".663","weight_em":"kg","basic_packaging":"3","shipping_packaging":"12","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6146_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004113711|Fuse link, NH1\/85 gG 50A\/1000V|Special fuses|Fuse links gG 1000V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|Mining fuses|NH1\/85 GG 50A\/10|Rated current 50A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 1000V|Indicator Top fuse status indicator|Breaking capacity AC 50kA|Power dissipation 7,6W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269|Application For cable protection|Fuse link NH1\/85 NH NH1 50A 1000V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"50","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"1000","rated_dc_voltage":"","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"50","breaking_capacity_dc":"","pd_w":"7,6","Standards":"IEC 60269","Power_dissip_07":"","Operating_joule":"","Prearcing_joule":"","Application":"zum Kabelschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004113711-sicherungseinsatz-nh1-85-nh-nh1-50a-1000-gg"},{"ID":"6088","eti_code":"004113712","descr":"NH1\/85 gG 63A\/1000V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/85 NH NH1 63A 1000 gG","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".663","weight_em":"kg","basic_packaging":"3","shipping_packaging":"12","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6146_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004113712|Fuse link, NH1\/85 gG 63A\/1000V|Special fuses|Fuse links gG 1000V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|Mining fuses|NH1\/85 GG 63A\/10|Rated current 63A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 1000V|Indicator Top fuse status indicator|Breaking capacity AC 50kA|Power dissipation 10W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269|Application For cable protection|Fuse link NH1\/85 NH NH1 63A 1000V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"63","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"1000","rated_dc_voltage":"","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"50","breaking_capacity_dc":"","pd_w":"10","Standards":"IEC 60269","Power_dissip_07":"","Operating_joule":"","Prearcing_joule":"","Application":"zum Kabelschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004113712-sicherungseinsatz-nh1-85-nh-nh1-63a-1000-gg"},{"ID":"7098","eti_code":"004113713","descr":"NH1\/85 gG 80A\/1000V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/85 NH NH1 80A 1000 gG","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".663","weight_em":"kg","basic_packaging":"3","shipping_packaging":"12","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6146_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004113713|Fuse link, NH1\/85 gG 80A\/1000V|Special fuses|Fuse links gG 1000V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|Mining fuses|NH1\/85 GG 80A\/10|Rated current 80A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 1000V|Indicator Top fuse status indicator|Breaking capacity AC 50kA|Power dissipation 10,5W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269|Application For cable protection|Fuse link NH1\/85 NH NH1 80A 1000V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"80","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"1000","rated_dc_voltage":"","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"50","breaking_capacity_dc":"","pd_w":"10,5","Standards":"IEC 60269","Power_dissip_07":"","Operating_joule":"","Prearcing_joule":"","Application":"zum Kabelschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004113713-sicherungseinsatz-nh1-85-nh-nh1-80a-1000-gg"},{"ID":"3178","eti_code":"004113714","descr":"NH1\/85 gG 100A\/1000V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/85 NH NH1 100A 1000 gG","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".663","weight_em":"kg","basic_packaging":"3","shipping_packaging":"12","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6146_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004113714|Fuse link, NH1\/85 gG 100A\/1000V|Special fuses|Fuse links gG 1000V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|Mining fuses|NH1\/85 GG 100A\/1|Rated current 100A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 1000V|Indicator Top fuse status indicator|Breaking capacity AC 50kA|Power dissipation 13W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269|Application For cable protection|Fuse link NH1\/85 NH NH1 100A 1000V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"100","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"1000","rated_dc_voltage":"","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"50","breaking_capacity_dc":"","pd_w":"13","Standards":"IEC 60269","Power_dissip_07":"","Operating_joule":"","Prearcing_joule":"","Application":"zum Kabelschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004113714-sicherungseinsatz-nh1-85-nh-nh1-100a-1000-gg"},{"ID":"3177","eti_code":"004113715","descr":"NH1\/85 gG 125A\/1000V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/85 NH NH1 125A 1000 gG","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".663","weight_em":"kg","basic_packaging":"3","shipping_packaging":"12","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6146_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004113715|Fuse link, NH1\/85 gG 125A\/1000V|Special fuses|Fuse links gG 1000V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|Mining fuses|NH1\/85 GG 125A\/1|Rated current 125A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 1000V|Indicator Top fuse status indicator|Breaking capacity AC 50kA|Power dissipation 16,9W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269|Application For cable protection|Fuse link NH1\/85 NH NH1 125A 1000V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"125","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"1000","rated_dc_voltage":"","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"50","breaking_capacity_dc":"","pd_w":"16,9","Standards":"IEC 60269","Power_dissip_07":"","Operating_joule":"","Prearcing_joule":"","Application":"zum Kabelschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004113715-sicherungseinsatz-nh1-85-nh-nh1-125a-1000-gg"},{"ID":"3195","eti_code":"004113716","descr":"NH1\/85 gG 160A\/1000V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/85 NH NH1 160A 1000 gG","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".663","weight_em":"kg","basic_packaging":"3","shipping_packaging":"12","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6146_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004113716|Fuse link, NH1\/85 gG 160A\/1000V|Special fuses|Fuse links gG 1000V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|Mining fuses|NH1\/85 GG 160A\/1|Rated current 160A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 1000V|Indicator Top fuse status indicator|Breaking capacity AC 50kA|Power dissipation 21W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269|Application For cable protection|Fuse link NH1\/85 NH NH1 160A 1000V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"160","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"1000","rated_dc_voltage":"","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"50","breaking_capacity_dc":"","pd_w":"21","Standards":"IEC 60269","Power_dissip_07":"","Operating_joule":"","Prearcing_joule":"","Application":"zum Kabelschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004113716-sicherungseinsatz-nh1-85-nh-nh1-160a-1000-gg"},{"ID":"7100","eti_code":"004113717","descr":"NH1\/85 gG 200A\/1000V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/85 NH NH1 200A 1000 gG","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".779","weight_em":"kg","basic_packaging":"3","shipping_packaging":"12","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6146_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004113717|Fuse link, NH1\/85 gG 200A\/1000V|Special fuses|Fuse links gG 1000V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|Mining fuses|NH1\/85 GG 200A\/1|Rated current 200A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 1000V|Indicator Top fuse status indicator|Breaking capacity AC 50kA|Power dissipation 24,8W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269|Application For cable protection|Fuse link NH1\/85 NH NH1 200A 1000V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"200","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"1000","rated_dc_voltage":"","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"50","breaking_capacity_dc":"","pd_w":"24,8","Standards":"IEC 60269","Power_dissip_07":"","Operating_joule":"","Prearcing_joule":"","Application":"zum Kabelschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004113717-sicherungseinsatz-nh1-85-nh-nh1-200a-1000-gg"},{"ID":"42223","eti_code":"004723259","descr":"NH1 BAT 40A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1 NH NH1 40A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".453","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723259|Fuse link, NH1 BAT 40A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator|Special purpose fuses|Battery protection fuses|NH1 BAT 40A\/550V|Rated current 40A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 6W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 2,7W|Operating joule integral 833A2s|L\/R 10ms|Prearcing joule integral 250A2s|Application Battery protection|Fuse link NH1 NH NH1 40A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"40","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"6","Standards":"IEC 60269","Power_dissip_07":"2,7","Operating_joule":"833","Prearcing_joule":"250","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723259-sicherungseinsatz-nh1-nh-nh1-40a-550-gbat-10ms"},{"ID":"20069","eti_code":"004723260","descr":"NH1 BAT 50A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1 NH NH1 50A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".453","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723260|Fuse link, NH1 BAT 50A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator|Special purpose fuses|Battery protection fuses|NH1 BAT 50A\/550V|Rated current 50A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 7W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 3,1W|Operating joule integral 1.495A2s|L\/R 10ms|Prearcing joule integral 449A2s|Application Battery protection|Fuse link NH1 NH NH1 50A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"50","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"7","Standards":"IEC 60269","Power_dissip_07":"3,1","Operating_joule":"1.495","Prearcing_joule":"449","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723260-sicherungseinsatz-nh1-nh-nh1-50a-550-gbat-10ms"},{"ID":"20070","eti_code":"004723261","descr":"NH1 BAT 63A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1 NH NH1 63A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".453","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723261|Fuse link, NH1 BAT 63A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator|Special purpose fuses|Battery protection fuses|NH1 BAT 63A\/550V|Rated current 63A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 9W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 4W|Operating joule integral 2.331A2s|L\/R 10ms|Prearcing joule integral 700A2s|Application Battery protection|Fuse link NH1 NH NH1 63A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"63","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"9","Standards":"IEC 60269","Power_dissip_07":"4","Operating_joule":"2.331","Prearcing_joule":"700","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723261-sicherungseinsatz-nh1-nh-nh1-63a-550-gbat-10ms"},{"ID":"20071","eti_code":"004723262","descr":"NH1 BAT 80A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1 NH NH1 80A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".453","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723262|Fuse link, NH1 BAT 80A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator|Special purpose fuses|Battery protection fuses|NH1 BAT 80A\/550V|Rated current 80A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 12W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 5,4W|Operating joule integral 3.996A2s|L\/R 10ms|Prearcing joule integral 1.200A2s|Application Battery protection|Fuse link NH1 NH NH1 80A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"80","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"12","Standards":"IEC 60269","Power_dissip_07":"5,4","Operating_joule":"3.996","Prearcing_joule":"1.200","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723262-sicherungseinsatz-nh1-nh-nh1-80a-550-gbat-10ms"},{"ID":"20072","eti_code":"004723263","descr":"NH1 BAT 100A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1 NH NH1 100A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".453","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723263|Fuse link, NH1 BAT 100A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator|Special purpose fuses|Battery protection fuses|NH1 BAT 100A\/550|Rated current 100A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 15W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 6,7W|Operating joule integral 5.495A2s|L\/R 10ms|Prearcing joule integral 1.650A2s|Application Battery protection|Fuse link NH1 NH NH1 100A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"100","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"15","Standards":"IEC 60269","Power_dissip_07":"6,7","Operating_joule":"5.495","Prearcing_joule":"1.650","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723263-sicherungseinsatz-nh1-nh-nh1-100a-550-gbat-10ms"},{"ID":"20073","eti_code":"004723264","descr":"NH1 BAT 125A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1 NH NH1 125A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".453","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723264|Fuse link, NH1 BAT 125A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator|Special purpose fuses|Battery protection fuses|NH1 BAT 125A\/550|Rated current 125A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 20W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 9W|Operating joule integral 7.326A2s|L\/R 10ms|Prearcing joule integral 2.200A2s|Application Battery protection|Fuse link NH1 NH NH1 125A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"125","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"20","Standards":"IEC 60269","Power_dissip_07":"9","Operating_joule":"7.326","Prearcing_joule":"2.200","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723264-sicherungseinsatz-nh1-nh-nh1-125a-550-gbat-10ms"},{"ID":"20074","eti_code":"004723265","descr":"NH1 BAT 160A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1 NH NH1 160A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".453","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/idents\/en-GB\/004723265_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723265|Fuse link, NH1 BAT 160A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator|Special purpose fuses|Battery protection fuses|NH1 BAT 160A\/550|Rated current 160A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 26W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 11,7W|Operating joule integral 14.319A2s|L\/R 10ms|Prearcing joule integral 4.300A2s|Application Battery protection|Fuse link NH1 NH NH1 160A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"160","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"26","Standards":"IEC 60269","Power_dissip_07":"11,7","Operating_joule":"14.319","Prearcing_joule":"4.300","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723265-sicherungseinsatz-nh1-nh-nh1-160a-550-gbat-10ms"},{"ID":"20075","eti_code":"004723266","descr":"NH1 BAT 200A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1 NH NH1 200A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".453","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723266|Fuse link, NH1 BAT 200A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator|Special purpose fuses|Battery protection fuses|NH1 BAT 200A\/550|Rated current 200A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 32W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 14,4W|Operating joule integral 28.305A2s|L\/R 10ms|Prearcing joule integral 8.500A2s|Application Battery protection|Fuse link NH1 NH NH1 200A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"200","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"32","Standards":"IEC 60269","Power_dissip_07":"14,4","Operating_joule":"28.305","Prearcing_joule":"8.500","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723266-sicherungseinsatz-nh1-nh-nh1-200a-550-gbat-10ms"},{"ID":"20076","eti_code":"004723267","descr":"NH1 BAT 224A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1 NH NH1 224A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".453","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723267|Fuse link, NH1 BAT 224A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator|Special purpose fuses|Battery protection fuses|NH1 BAT 224A\/550|Rated current 224A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 37W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 16,6W|Operating joule integral 33.300A2s|L\/R 10ms|Prearcing joule integral 10.000A2s|Application Battery protection|Fuse link NH1 NH NH1 224A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"224","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"37","Standards":"IEC 60269","Power_dissip_07":"16,6","Operating_joule":"33.300","Prearcing_joule":"10.000","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723267-sicherungseinsatz-nh1-nh-nh1-224a-550-gbat-10ms"},{"ID":"20077","eti_code":"004723268","descr":"NH1 BAT 250A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1 NH NH1 250A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".453","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723268|Fuse link, NH1 BAT 250A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator|Special purpose fuses|Battery protection fuses|NH1 BAT 250A\/550|Rated current 250A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 43W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 19,3W|Operating joule integral 50.000A2s|L\/R 10ms|Prearcing joule integral 15.000A2s|Application Battery protection|Fuse link NH1 NH NH1 250A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"250","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"43","Standards":"IEC 60269","Power_dissip_07":"19,3","Operating_joule":"50.000","Prearcing_joule":"15.000","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723268-sicherungseinsatz-nh1-nh-nh1-250a-550-gbat-10ms"},{"ID":"42224","eti_code":"004723269","descr":"NHS1\/110 BAT 40A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NHS1\/110 NH NH1 40A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".49","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723269|Fuse link, NHS1\/110 BAT 40A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator S110mm|Special purpose fuses|Battery protection fuses|NHS1\/110 BAT 40A|Rated current 40A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Dimensions S110mm|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 6W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 2,7W|Operating joule integral 833A2s|L\/R 10ms|Prearcing joule integral 250A2s|Application Battery protection|Fuse link NHS1\/110 NH NH1 40A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"40","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"S110mm","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"6","Standards":"IEC 60269","Power_dissip_07":"2,7","Operating_joule":"833","Prearcing_joule":"250","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723269-sicherungseinsatz-nhs1-110-nh-nh1-40a-550-gbat-10ms"},{"ID":"42225","eti_code":"004723270","descr":"NHS1\/110 BAT 50A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NHS1\/110 NH NH1 50A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".49","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723270|Fuse link, NHS1\/110 BAT 50A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator S110mm|Special purpose fuses|Battery protection fuses|NHS1\/110 BAT 50A|Rated current 50A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Dimensions S110mm|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 7W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 3,1W|Operating joule integral 1.495A2s|L\/R 10ms|Prearcing joule integral 449A2s|Application Battery protection|Fuse link NHS1\/110 NH NH1 50A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"50","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"S110mm","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"7","Standards":"IEC 60269","Power_dissip_07":"3,1","Operating_joule":"1.495","Prearcing_joule":"449","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723270-sicherungseinsatz-nhs1-110-nh-nh1-50a-550-gbat-10ms"},{"ID":"42226","eti_code":"004723271","descr":"NHS1\/110 BAT 63A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NHS1\/110 NH NH1 63A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".49","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723271|Fuse link, NHS1\/110 BAT 63A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator S110mm|Special purpose fuses|Battery protection fuses|NHS1\/110 BAT 63A|Rated current 63A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Dimensions S110mm|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 9W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 4W|Operating joule integral 2.331A2s|L\/R 10ms|Prearcing joule integral 700A2s|Application Battery protection|Fuse link NHS1\/110 NH NH1 63A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"63","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"S110mm","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"9","Standards":"IEC 60269","Power_dissip_07":"4","Operating_joule":"2.331","Prearcing_joule":"700","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723271-sicherungseinsatz-nhs1-110-nh-nh1-63a-550-gbat-10ms"},{"ID":"20078","eti_code":"004723272","descr":"NHS1\/110 BAT 80A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NHS1\/110 NH NH1 80A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".49","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723272|Fuse link, NHS1\/110 BAT 80A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator S110mm|Special purpose fuses|Battery protection fuses|NHS1\/110 BAT 80A|Rated current 80A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Dimensions S110mm|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 12W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 5,4W|Operating joule integral 3.996A2s|L\/R 10ms|Prearcing joule integral 1.200A2s|Application Battery protection|Fuse link NHS1\/110 NH NH1 80A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"80","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"S110mm","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"12","Standards":"IEC 60269","Power_dissip_07":"5,4","Operating_joule":"3.996","Prearcing_joule":"1.200","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723272-sicherungseinsatz-nhs1-110-nh-nh1-80a-550-gbat-10ms"},{"ID":"20079","eti_code":"004723273","descr":"NHS1\/110 BAT 100A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NHS1\/110 NH NH1 100A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".49","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723273|Fuse link, NHS1\/110 BAT 100A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator S110mm|Special purpose fuses|Battery protection fuses|NHS1\/110 BAT 100|Rated current 100A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Dimensions S110mm|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 15W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 6,7W|Operating joule integral 5.495A2s|L\/R 10ms|Prearcing joule integral 1.650A2s|Application Battery protection|Fuse link NHS1\/110 NH NH1 100A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"100","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"S110mm","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"15","Standards":"IEC 60269","Power_dissip_07":"6,7","Operating_joule":"5.495","Prearcing_joule":"1.650","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723273-sicherungseinsatz-nhs1-110-nh-nh1-100a-550-gbat-10ms"},{"ID":"20080","eti_code":"004723274","descr":"NHS1\/110 BAT 125A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NHS1\/110 NH NH1 125A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".49","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723274|Fuse link, NHS1\/110 BAT 125A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator S110mm|Special purpose fuses|Battery protection fuses|NHS1\/110 BAT 125|Rated current 125A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Dimensions S110mm|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 20W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 9W|Operating joule integral 7.326A2s|L\/R 10ms|Prearcing joule integral 2.200A2s|Application Battery protection|Fuse link NHS1\/110 NH NH1 125A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"125","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"S110mm","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"20","Standards":"IEC 60269","Power_dissip_07":"9","Operating_joule":"7.326","Prearcing_joule":"2.200","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723274-sicherungseinsatz-nhs1-110-nh-nh1-125a-550-gbat-10ms"},{"ID":"20081","eti_code":"004723275","descr":"NHS1\/110 BAT 160A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NHS1\/110 NH NH1 160A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".49","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723275|Fuse link, NHS1\/110 BAT 160A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator S110mm|Special purpose fuses|Battery protection fuses|NHS1\/110 BAT 160|Rated current 160A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Dimensions S110mm|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 26W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 11,7W|Operating joule integral 14.319A2s|L\/R 10ms|Prearcing joule integral 4.300A2s|Application Battery protection|Fuse link NHS1\/110 NH NH1 160A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"160","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"S110mm","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"26","Standards":"IEC 60269","Power_dissip_07":"11,7","Operating_joule":"14.319","Prearcing_joule":"4.300","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723275-sicherungseinsatz-nhs1-110-nh-nh1-160a-550-gbat-10ms"},{"ID":"20082","eti_code":"004723276","descr":"NHS1\/110 BAT 200A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NHS1\/110 NH NH1 200A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".49","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723276|Fuse link, NHS1\/110 BAT 200A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator S110mm|Special purpose fuses|Battery protection fuses|NHS1\/110 BAT 200|Rated current 200A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Dimensions S110mm|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 32W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 14,4W|Operating joule integral 28.305A2s|L\/R 10ms|Prearcing joule integral 8.500A2s|Application Battery protection|Fuse link NHS1\/110 NH NH1 200A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"200","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"S110mm","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"32","Standards":"IEC 60269","Power_dissip_07":"14,4","Operating_joule":"28.305","Prearcing_joule":"8.500","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723276-sicherungseinsatz-nhs1-110-nh-nh1-200a-550-gbat-10ms"},{"ID":"20083","eti_code":"004723277","descr":"NHS1\/110 BAT 224A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NHS1\/110 NH NH1 224A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".49","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723277|Fuse link, NHS1\/110 BAT 224A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator S110mm|Special purpose fuses|Battery protection fuses|NHS1\/110 BAT 224|Rated current 224A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Dimensions S110mm|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 37W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 16,6W|Operating joule integral 33.300A2s|L\/R 10ms|Prearcing joule integral 10.000A2s|Application Battery protection|Fuse link NHS1\/110 NH NH1 224A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"224","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"S110mm","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"37","Standards":"IEC 60269","Power_dissip_07":"16,6","Operating_joule":"33.300","Prearcing_joule":"10.000","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723277-sicherungseinsatz-nhs1-110-nh-nh1-224a-550-gbat-10ms"},{"ID":"19269","eti_code":"004723278","descr":"NHS1\/110 BAT 250A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NHS1\/110 NH NH1 250A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".49","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723278|Fuse link, NHS1\/110 BAT 250A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Standard indicator S110mm|Special purpose fuses|Battery protection fuses|NHS1\/110 BAT 250|Rated current 250A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Dimensions S110mm|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 43W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 19,3W|Operating joule integral 50.000A2s|L\/R 10ms|Prearcing joule integral 15.000A2s|Application Battery protection|Fuse link NHS1\/110 NH NH1 250A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"250","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"S110mm","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"43","Standards":"IEC 60269","Power_dissip_07":"19,3","Operating_joule":"50.000","Prearcing_joule":"15.000","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723278-sicherungseinsatz-nhs1-110-nh-nh1-250a-550-gbat-10ms"},{"ID":"42227","eti_code":"004723279","descr":"NH1\/K BAT 40A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/K NH NH1 40A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".465","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723279|Fuse link, NH1\/K BAT 40A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Striker indicator|Special purpose fuses|Battery protection fuses|NH1\/K BAT 40A\/55|Rated current 40A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 6W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 2,7W|Operating joule integral 833A2s|L\/R 10ms|Prearcing joule integral 250A2s|Application Battery protection|Fuse link NH1\/K NH NH1 40A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"40","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"6","Standards":"IEC 60269","Power_dissip_07":"2,7","Operating_joule":"833","Prearcing_joule":"250","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723279-sicherungseinsatz-nh1-k-nh-nh1-40a-550-gbat-10ms"},{"ID":"19270","eti_code":"004723280","descr":"NH1\/K BAT 50A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/K NH NH1 50A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".42","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723280|Fuse link, NH1\/K BAT 50A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Striker indicator|Special purpose fuses|Battery protection fuses|NH1\/K BAT 50A\/55|Rated current 50A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 7W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 3,1W|Operating joule integral 1.495A2s|L\/R 10ms|Prearcing joule integral 449A2s|Application Battery protection|Fuse link NH1\/K NH NH1 50A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"50","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"7","Standards":"IEC 60269","Power_dissip_07":"3,1","Operating_joule":"1.495","Prearcing_joule":"449","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723280-sicherungseinsatz-nh1-k-nh-nh1-50a-550-gbat-10ms"},{"ID":"19271","eti_code":"004723281","descr":"NH1\/K BAT 63A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/K NH NH1 63A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".453","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723281|Fuse link, NH1\/K BAT 63A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Striker indicator|Special purpose fuses|Battery protection fuses|NH1\/K BAT 63A\/55|Rated current 63A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 9W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 4W|Operating joule integral 2.331A2s|L\/R 10ms|Prearcing joule integral 700A2s|Application Battery protection|Fuse link NH1\/K NH NH1 63A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"63","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"9","Standards":"IEC 60269","Power_dissip_07":"4","Operating_joule":"2.331","Prearcing_joule":"700","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723281-sicherungseinsatz-nh1-k-nh-nh1-63a-550-gbat-10ms"},{"ID":"19272","eti_code":"004723282","descr":"NH1\/K BAT 80A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/K NH NH1 80A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".453","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723282|Fuse link, NH1\/K BAT 80A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Striker indicator|Special purpose fuses|Battery protection fuses|NH1\/K BAT 80A\/55|Rated current 80A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 12W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 5,4W|Operating joule integral 3.996A2s|L\/R 10ms|Prearcing joule integral 1.200A2s|Application Battery protection|Fuse link NH1\/K NH NH1 80A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"80","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"12","Standards":"IEC 60269","Power_dissip_07":"5,4","Operating_joule":"3.996","Prearcing_joule":"1.200","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723282-sicherungseinsatz-nh1-k-nh-nh1-80a-550-gbat-10ms"},{"ID":"19273","eti_code":"004723283","descr":"NH1\/K BAT 100A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/K NH NH1 100A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".453","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723283|Fuse link, NH1\/K BAT 100A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Striker indicator|Special purpose fuses|Battery protection fuses|NH1\/K BAT 100A\/5|Rated current 100A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 15W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 6,7W|Operating joule integral 5.495A2s|L\/R 10ms|Prearcing joule integral 1.650A2s|Application Battery protection|Fuse link NH1\/K NH NH1 100A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"100","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"15","Standards":"IEC 60269","Power_dissip_07":"6,7","Operating_joule":"5.495","Prearcing_joule":"1.650","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723283-sicherungseinsatz-nh1-k-nh-nh1-100a-550-gbat-10ms"},{"ID":"19274","eti_code":"004723284","descr":"NH1\/K BAT 125A\/550V DC","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Sicherungseinsatz NH1\/K NH NH1 125A 550 gBAT 10ms","seo_alias":null,"class_name":"Sicherungseinsatz","id_level":"57","weight":".453","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4111_photo.jpg","tree_depth":"1","tree_title":"Sicherungseins\u00e4tze f\u00fcr Sonderzwecke","program_type":"1","pim_status":"","searchstring":"|004723284|Fuse link, NH1\/K BAT 125A\/550V DC|Special fuses|Battery fuses|550 V d.c.|NV1|NV1|Striker indicator|Special purpose fuses|Battery protection fuses|NH1\/K BAT 125A\/5|Rated current 125A|Type NH|Rated voltage 550V|Size NH1|Product group Special purpose fuses|Product subgroup BATT|Characteristics gBAT|Rated DC voltage 550V|Indicator Top fuse status indicator|Breaking capacity DC 30kA|Power dissipation 20W|Catalogue Group Special purpose fuses|Catalogue subgroup Battery Fuse|Standards IEC 60269|Power dissipation (0,7xIn) 9W|Operating joule integral 7.326A2s|L\/R 10ms|Prearcing joule integral 2.200A2s|Application Battery protection|Fuse link NH1\/K NH NH1 125A 550V gBAT 10ms|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"125","type":"NH","size":"NH1","charact":"gBAT","rated_ac_voltage":"","rated_dc_voltage":"550","dimensions":"","indicator":"Statusanzeige der oberen Sicherung","breaking_capacity_ac":"","breaking_capacity_dc":"30","pd_w":"20","Standards":"IEC 60269","Power_dissip_07":"9","Operating_joule":"7.326","Prearcing_joule":"2.200","Application":"Batterieschutz","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723284-sicherungseinsatz-nh1-k-nh-nh1-125a-550-gbat-10ms"}],"columns":[{"name":"eti_code","title":"ETI Artikel-Nummer ","primary":true},{"name":"descr","title":"Beschreibung","primary":false},{"name":"class_name","title":"Klassifizierungsname","primary":false},{"name":"type","title":"Typ","primary":false},{"name":"Price","title":"Preis","cssClass":"price align-right","primary":false},{"name":"StockStatus","title":"Verf\u00fcgbarkeit","primary":false},{"name":"Commands","title":"","primary":false}],"recordsCount":40,"recordsTotalCount":839,"params":{"filters":{"lang":"de-DE","levelId":57,"status":null,"search":null,"programType":"actual"},"pageNumber":1,"pageSize":40,"pageMax":21,"dataEx":{"filterItems":{"type":{"field":"type","values":[{"count":"47","value":"CH"},{"count":"25","value":"CH SU"},{"count":"30","value":"DB"},{"count":"717","value":"NH"},{"count":"7","value":"SZDB"},{"count":"12","value":"TRB"}],"trans":"Typ"},"size":{"field":"size","values":[{"count":"6","value":"01XL"},{"count":"68","value":"1XL"},{"count":"42","value":"2XL"},{"count":"64","value":"3L"},{"count":"53","value":"CH10"},{"count":"14","value":"CH14"},{"count":"5","value":"CH22"},{"count":"8","value":"DB1"},{"count":"1","value":"DB2"},{"count":"3","value":"DB3"},{"count":"1","value":"DB4"},{"count":"7","value":"DB5"},{"count":"9","value":"DB6"},{"count":"1","value":"DB7"},{"count":"10","value":"NH0"},{"count":"73","value":"NH00"},{"count":"3","value":"NH00C"},{"count":"24","value":"NH000"},{"count":"1","value":"NH000L"},{"count":"184","value":"NH1"},{"count":"20","value":"NH1C"},{"count":"120","value":"NH2"},{"count":"89","value":"NH3"},{"count":"11","value":"NH4a"},{"count":"2","value":"Other"},{"count":"7","value":"S368"}],"trans":"Gr\u00f6\u00dfe"},"rated_current":{"field":"rated_current","values":[{"count":"1","value":"0,5"},{"count":"1","value":"1"},{"count":"5","value":"2"},{"count":"6","value":"4"},{"count":"9","value":"6"},{"count":"2","value":"7,5"},{"count":"6","value":"8"},{"count":"13","value":"10"},{"count":"6","value":"12"},{"count":"1","value":"15"},{"count":"16","value":"16"},{"count":"22","value":"20"},{"count":"20","value":"25"},{"count":"4","value":"30"},{"count":"19","value":"32"},{"count":"13","value":"35"},{"count":"2","value":"36"},{"count":"33","value":"40"},{"count":"39","value":"50"},{"count":"4","value":"60"},{"count":"41","value":"63"},{"count":"3","value":"70"},{"count":"42","value":"80"},{"count":"51","value":"100"},{"count":"59","value":"125"},{"count":"3","value":"150"},{"count":"64","value":"160"},{"count":"68","value":"200"},{"count":"18","value":"224"},{"count":"64","value":"250"},{"count":"1","value":"300"},{"count":"45","value":"315"},{"count":"33","value":"350"},{"count":"2","value":"355"},{"count":"39","value":"400"},{"count":"9","value":"425"},{"count":"7","value":"450"},{"count":"20","value":"500"},{"count":"15","value":"630"},{"count":"5","value":"800"},{"count":"3","value":"1000"},{"count":"2","value":"1250"}],"trans":"Bemessungsstrom (A)"},"rated_ac_voltage":{"field":"rated_ac_voltage","values":[{"count":"46","value":"400"},{"count":"39","value":"500"},{"count":"5","value":"600"},{"count":"18","value":"690"},{"count":"45","value":"800"},{"count":"71","value":"1000"},{"count":"75","value":"1200"},{"count":"4","value":"1500"},{"count":"13","value":"3000"}],"trans":"Bemessungsspannung AC"},"rated_dc_voltage":{"field":"rated_dc_voltage","values":[{"count":"44","value":"80"},{"count":"12","value":"250"},{"count":"38","value":"440"},{"count":"7","value":"450"},{"count":"7","value":"500"},{"count":"93","value":"550"},{"count":"75","value":"700"},{"count":"73","value":"800"},{"count":"59","value":"1000"},{"count":"53","value":"1100"},{"count":"52","value":"1500"},{"count":"13","value":"3000"},{"count":"37","value":"4000"},{"count":"7","value":"5000"}],"trans":"Bemessungsspannung DC"},"charact":{"field":"charact","values":[{"count":"23","value":"aM"},{"count":"40","value":"aR"},{"count":"11","value":"gB"},{"count":"402","value":"gBAT"},{"count":"14","value":"gCP"},{"count":"134","value":"gG"},{"count":"96","value":"gR"},{"count":"7","value":"gR (general purpose semiconductor protection)"},{"count":"20","value":"gS"},{"count":"21","value":"gTr"},{"count":"1","value":"Other"}],"trans":"Charakteristiken"}},"columnsThumbs":[{"column":"class_name","title":"Klassifizierungsname"},{"column":"type","title":"Typ"},{"column":"size","title":"Gr\u00f6\u00dfe"},{"column":"rated_current","title":"Bemessungsstrom (A)"},{"column":"rated_ac_voltage","title":"Bemessungsspannung AC"}],"columnsThumbsAll":[{"column":"class_name","title":"Klassifizierungsname"},{"column":"type","title":"Typ"},{"column":"size","title":"Gr\u00f6\u00dfe"},{"column":"rated_current","title":"Bemessungsstrom (A)"},{"column":"rated_ac_voltage","title":"Bemessungsspannung AC"},{"column":"rated_dc_voltage","title":"Bemessungsspannung DC"},{"column":"charact","title":"Charakteristiken"},{"column":"breaking_capacity_ac","title":"Abschaltleistung AC"},{"column":"breaking_capacity_dc","title":"Abschaltleistung DC"},{"column":"Application","title":"Anwendung"}],"programTypes":[{"program_type":"0","Count":"11"},{"program_type":"1","Count":"839"}]}}}